Q Is there a fan connector for the PD3 Series units?

A

The PD3 Series units do not have a connector output that can be used for fans.

QA No. 12-0009

Q During PD3 Series communication, are there any issues when other devices are connected?

A

<For cases where standards and pin configurations are the same>

Although communication is not possible due to differences in communication protocols,
nothing will malfunction or be damaged even if they are connected.

<For cases where standards and pin configurations are different>

If voltages and input/output pin configurations are different and they are connected, this can result in malfunction or damage,
so we strictly prohibit this.

Q Are connectors included for the PD3 Series units?

A

1.ON/OFF (trigger)

Not included.
Please make use of an optional trigger input cable (sold separately).

2.Dimming control
a) Parallel

Not included.
Please make use of an optional parallel communication cable (sold separately).

b) Serial

Not included.
Please make use of an optional EIA-485 communication relay cable (sold separately).

c)Ethernet

Not included.
Please make use of consumer LAN cable.

QA No. 12-0007

Q What would happen if a PD3 Series unit was used in a usage environment with a temperature that exceeds 40°C?

A

A voltage drop and a decrease in product service life would occur, preventing the product from providing the specified performance.
Please make use of the product within the specified usage temperature range.

QA No. 12-0006

Q What is the threshold voltage for the PD3 Series (AC type) photo coupler?

A

ON voltage: DC 14.4V or higher, ON current: 3mA or lower
OFF voltage: DC 5V or lower, OFF current: 1mA or lower

QA No. 12-0004

Q What would happen if a light unit were to be connected to the same channel as a HLV Light and 24V Light, when using a PD3-5024-4 Series or PD3-10024-8 Series unit (AC input type)?

A

It would be the same as when each of the units were connected individually.
Please note, however, that dimming would only be performed in a single location.

QA No. 12-0003

Q When using a PD3-5024-4 Series or PD3-10024-8 Series unit (AC input type), are there any issues if a HLV unit is connected to a 24V Light connector?

A

It will light up but the light will be weak.
Fundamentally, no damage should occur to either the power source or light unit.

QA No. 12-0002

Q Is it possible to make the lighting turn off, when dimming value is set to 0 for the PD3 Series (AC input type)?

A

This is possible for a custom order product.
For more details, please inquire at our various sales offices.

QA No. 12-0001

Q Is there a table that compares the PD2-3024 Series and PD3-3024 Series?

A

A table comparing the PD2-3024 Series and PD3-3024 Series units is given below.
(Common specifications for PI, SI, and EI.)

QA No. 12-0001

Q How can the PD3-3024-3-EI/PD3-5024-4-SI/PD3-10024-8-SI (EIA-485 type) communication cable be connected?

A

Identification is performed using the ID switch configurations,
and up to 4 units can be connected to a single signal line.
Please read the following before connecting:
PD3_EIA-485_jp.pdf

QA No. 11-0165

Q Is there any way to keep a PD3-3024-3 Series unit fastened without having to remove the rubber feet and use the optional bracket?

A

This is not possible since the plastic chassis would come into contact with other objects.
Please make use of the optional bracket.

QA No. 11-0165

Q Does the "EIA485 type" for the PD3-3024-3-SI unit refer to the same thing as RS-485?

A

It refers to a standardized version of RS-485.

QA No. 11-0164

Q For the QPD3-3024-3 Series, is it possible to change the PWM frequency?

A

This is possible for some custom order units.
Aside from 125kHz, 62.5kHz, 250kHz, and 50kHz can also be provided as options.
For more details please contact one of our various sales offices.

QA No. 11-0163

Q Do the PD3-3024-3 Series units have a fan Control Unit connector?

A

The PD3-3024-3 Series units do not have a connector output that can be used for fans.

QA No. 11-0161

Q Can a PD3-3024-3 Series unit be used while connected with a STU-3000 unit?

A

They can be connected.
Although it will not be possible to control precise light-emitting time settings, the PD3-3024-3 Series units are equipped with a strobe function equivalent to that of the STU-3000 units.

QA No. 11-0159

Q Are there any precautions to observe when performing external control communication for PD3-3024-3 Series units?

A

-Serial (EIA-485) communication type:

Although the standard is basically the same as that for EIA-485, based on internal evaluations, 30m or more for maximum transmission distance cannot be guaranteed.

-Ethernet communication type:

Please exercise caution when configuring IP addresses and subnet masks.
Even for usage environments where multiple units are connected, Ethernet settings, such as IP addresses, etc., can only be performed on a 1 to 1 basis.

QA No. 11-0158

Q How many degrees is the heat generated by a PD3-3024-3 Series unit?

A

At a maximum dimming load and 30W power consumption, it would be 55°C when used in a 40°C environment.

QA No. 11-0152

Q What is the mounting orientation for a PD3-3024-3 Series unit?

A

It is possible to mount the unit in a vertical manner.
Mounting orientations that requires the plastic case to act as the fastening surface are prohibited, due to strength issues.

QA No. 11-0151

Q Are there mounting methods for the PD3-3024-3 Series units that don't involve the use of a DIN rail?

A

It is possible to remove the rubber feet and to use an optional bracket to fasten the unit.

QA No. 11-0150

Q When using a PD3-3024-3 Series unit, if an error occurs, will the unit recover on its own?

A

It cannot recover on its own.
After the cause of the error is rectified,
please restart the primary power source.

QA No. 11-0148

Q How can a PD3 Series unit be cleaned if it has been soiled?

A

When cleaning the chassis, please use a soft rag that has been dipped in water containing diluted neutral detergent, and thoroughly wring out the rag before lightly wiping away the stains, and finally use a separate soft rag to wipe it dry.

  • -Before performing cleaning, shut down power and unplug the unit from the power outlet.
  • -Do not damage the unit by letting it come into contact with hard objects.
  • -Do not let water or detergent come into contact with the unit's internal parts.
  • -Do not use any detergents/chemicals other than neutral detergent.

QA No. 11-0147

Q What is the response time for a PD3-3024-3 Series unit?

A

OFF to ON: 10μs or less, ON to OFF: 10μs or less

QA No. 11-0146

Q What cable is recommended when using a PD3 Series unit at AC 200V?

A

When using the unit at AC 200-240V, we recommend usage of the following types of cables.
H05VV-F type, AWG18, cable length of 3 meters or longer, dielectric strength of 250V or higher
Control Unit-side AC inlet standard: EN60320-1 C14 type
AC cord-side socket standard: EN60320-1 C13 type

QA No. 11-0145

Q What is the dimming value compatibility and linearity between the PD3-3024-3 Series and PD2?

A

They are not completely compatible due to differences in frequency and FET gate voltage differences.
Additionally, linearity is roughly equivalent.

QA No. 11-0144

Q Are there any noise related issues for the PD3 Series?

A

Since it depends on the usage environment, although it is hard to say for sure, since the units for this series perform external control using photo coupler input and they are equipped with noise suppressing countermeasures based on the techniques we have refined over the years, it is fair to say that they are more resistant than the PD2 Series.

QA No. 11-0143